Insulated Rimboard Evaluation
EMERCOR Structural Insulated Panels are comprised of materials, which meet or exceed the standards, which are recognized by evaluation services in Canada and the United States, such as CCMC, ICBO, NER etc. EMERCOR Panels are similar to other engineered products like the roof truss.
EMERCOR panels have been tested to determine their physical capabilities. Independent registered professional engineers have prepared load tables for use in the review and approval of EMERCOR panels on each project.
The individual components used to produce an EMERCOR panel conform to the following standards:
|
COMPONENT PHYSICAL PROPERTIES |
VALUE |
STANDARDS |
|
Polyurethane Rigid Foam View
MSDS  |
|
|
Molded Panel |
2.25 pcf |
ASTM D-1622 |
Core Density |
1.94 pcf |
ASTM D-1622 |
| |
|
|
Parallel Compressive Strength @ 10% deflection |
31 psi |
ASTM D-1621 |
Parallel Compressive Modulus |
721 psi |
ASTM D-1621 |
| |
|
|
Perpendicular Compressive Strength @ 10% deflection |
16 psi |
ASTM D-1621 |
Perpendicular Compressive Modulus |
433 psi |
ASTM D-1621 |
| |
|
|
Flexural strength |
49 psi |
ASTM D-790 |
| |
|
|
Tensile Strength |
49 psi |
ASTM D-1623 |
| |
|
|
Porosity (%Closed cells) |
92% |
ASTM D-2856 |
| |
|
|
Water absorption (%) |
1.6 |
ASTM D-2842 |
| |
|
|
"k" factor, BTU-IN/HR-FT2-°F |
|
|
Initial |
0.146 |
ASTM C-518 |
Aged 10 days @ 140°F |
0.159 |
ASTM C-518 |
| |
|
|
"R" value, /inch of thickness |
6.85 |
|
"R" value aged 10 days @ 140°F /inch of thickness |
6.29 |
ASTM C-177-85 |
| |
|
|
Flame Spread* |
20 |
ASTM E-84 |
E-84 Smoke |
450 |
ASTM E-84 |
| |
|
|
|
Oriented Strand Board (OSB) |
|
CSA 0325.0
NER-108
PS 2-92
HUD&FHA #1100A |
| |
|
|
Gypsum Drywall |
|
ASTM C36
CSA A82.27-M |
| |
|
|
PWF Plywood |
|
CSA 0121-M
CSA 0151-M
CSA 0322 |
|
| * This numerical flame spread rating is not intended to reflect hazards presented by this or any other material under actual fire conditions. |
The following tests have been performed on the EMERCOR Structural Insulated Panel System:
Axial Compression Test |
ASTM E72-80
(Section 9) |
Simple Bending Test |
ASTM E72-80
(Section 11) |
Static Load Test for Shear Resistance (Racking Shear) |
ASTM E564-76 |
Spline Shear Test of Wall to Wall Connection Assembly |
ASTM E72-95 |
back to top
Insulated Rimboard Evaluation
EMERCOR Insulated Rimboard is an ICC (International Code Council) evaluated product. Design specifications for wood construction (1991 edition for the UBC and 1997 edition for the IBC and IRC) are applicable for EMERCOR Insulated Rimboard.
The quality system in place for the manufacture of Insulated Rimboard is approved and monitored by PFS Corporation, a third party quality control agency. The following allowable stresses comply with EMERCOR's Insulated Rimboard ICC evaluation.
TEST (Depth <16") |
VALUE |
Vertical Loading |
2,100 lbs/ft |
| |
|
Lateral Loading |
180 plf |
| |
|
Vertical Fastener Capacity
- 3/8" X 5" Lag Screw w/washer
- 1/2" X 5" Lag Screw w/washer
- 1/2" X 5" through bolt with nuts & washer on both sides
- 1/8'' (#8) X 4" Screw
|
280 lbs
310 lbs
410 lbs
150 lbs
|